欢迎来北京祥生兴业科技有限公司!我们将为您提供周到的服务!
相关文章Related articles

产品名称:CDT血清质控品

产品型号:0168/0169

产品报价:

产品特点:

英文名:0168CDTSerumControl

免费咨询:13681184382

发邮件给我们:702140183@qq.com

分享到:

0168/0169CDT血清质控品的详细资料:

温馨提示:仅用于科研,不可用于临床治疗

  • 英文名:

    0168 CDT Serum Control, Level I, 5 x 1 ml / 0169 CDT Serum Control, Level II, 5 x 1 ml

  • 供应商:

    祥生兴业

  • 保存条件:

    低温

    CDT

    • Reagent kit
    • Controls
    • 0168 CDT Serum Control, Level I, 5 x 1 ml
    • 0169 CDT Serum Control, Level II, 5 x 1 ml


    CDT Serum Controls

    Concentrations (example)

    Please note: All concentrations shown here are exemplatory. They do not reflect real data for the described products. Actual concentrations depend on the production lot of each product and can exclusively be found in the product information leaflet. Please ask for these product information leaflets or download them from the service site of the Chromsystems website.

    Substance Value [µg/l]
    Level I
    Range [µg/l]
    Level I
    Value [µg/l]
    Level II
    Range [µg/l]
    Level II
    Asialotransferrin < 0.3 % -
    < 0.3 %
    -
    Monosialotransferrin 0 % - 0 % -
    Disialotransferrin 1.69 % 1.27-2.11 % 3.06 % 2.45-3.67 %
    Trisialotransferrin 4.48 % 3.36-5.60 % 4.38 % 3.50-5.25 %
    Tetrasialotransferrin 86.5 % 77.8-95.1 % 85.8 % 77.2-94.4 %
    Pentasialotransferrin 7.37 % 5.16-9.58 % 6.79 % 4.75-8.82 %

    Instructions

    These Chromsystems plasma controls are designed to monitor the accuracy and precision of analytical procedures for the quantitative determination of CDT in serum. The lyophilised controls are based on human serum and should be used routinely according to the instructions of the assay procedure being used. While following these instructions the control is to be handled in the same manner as a patient specimen.

    Reconstitution

    Remove the metal seal and rubber stopper from the vial. Add exactly 1.0 ml of double distilled water (possibly HPLC-grade) into the vial. Replace the stopper and allow to sit for 10 to 15 min. Swirl the vial to dissolve the contents until homogeneity.

    Storage conditions

    Stored at <-18 °C unopened controls are stable until the expiry date which is stated on the vial labels. The reconstituted control can be stored up to 5 days tightly capped at +2 to +8 °C. If the controls cannot be analysed within this period, they should be aliquoted and stored frozen at <-18 °C (up to 3 months).

    Ordering information

    0168 CDT Serum Control (lyoph.), Level I, 5 x 1 ml
    0169 CDT Serum Control (lyoph.), Level II, 5 x 1 ml
    产品信息 http://chromsystems.com/en-gb/produkte/cdt